{"id":346,"date":"2022-03-10T11:35:00","date_gmt":"2022-03-10T10:35:00","guid":{"rendered":"http:\/\/au.feri.um.si\/leoss\/?p=346"},"modified":"2022-03-10T11:35:00","modified_gmt":"2022-03-10T10:35:00","slug":"fiber-optic-microbend-sensor-structure","status":"publish","type":"post","link":"https:\/\/au.jovo.cc\/leoss\/fiber-optic-microbend-sensor-structure\/","title":{"rendered":"Fiber-optic microbend sensor structure"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">We proposed and experimentally investigated a novel microbend sensor structure. The structure is composed of single-mode leads and multimode sensing fiber. The proposed structure exhibited a level of sensitivity as much as six times higher than that of the classical microbend sensor configuration when the same sensing fiber was used. Additionally, single-mode leads reduce lead noise and allow the use of more-coherent sources. The total loss of the proposed nondeformed structure is near 2 dB when the proper splicing method is used.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.osapublishing.org\/ol\/abstract.cfm?uri=ol-22-11-837\">https:\/\/www.osapublishing.org\/ol\/abstract.cfm?uri=ol-22-11-837<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>We proposed and experimentally investigated a novel microbend sensor structure. The structure is composed of single-mode leads and multimode sensing fiber. The proposed structure exhibited a level of sensitivity as much as six times higher than that of the classical microbend sensor configuration when the same sensing fiber was used. Additionally, single-mode leads reduce lead [&hellip;]<\/p>\n","protected":false},"author":0,"featured_media":1272,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[12,5,20],"tags":[],"class_list":["post-346","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-opticna-vlakna-pasivne","category-raziskovalno-delo","category-sms-structure-and-mode-coupling"],"_links":{"self":[{"href":"https:\/\/au.jovo.cc\/leoss\/wp-json\/wp\/v2\/posts\/346","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/au.jovo.cc\/leoss\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/au.jovo.cc\/leoss\/wp-json\/wp\/v2\/types\/post"}],"replies":[{"embeddable":true,"href":"https:\/\/au.jovo.cc\/leoss\/wp-json\/wp\/v2\/comments?post=346"}],"version-history":[{"count":0,"href":"https:\/\/au.jovo.cc\/leoss\/wp-json\/wp\/v2\/posts\/346\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/au.jovo.cc\/leoss\/wp-json\/wp\/v2\/media\/1272"}],"wp:attachment":[{"href":"https:\/\/au.jovo.cc\/leoss\/wp-json\/wp\/v2\/media?parent=346"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/au.jovo.cc\/leoss\/wp-json\/wp\/v2\/categories?post=346"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/au.jovo.cc\/leoss\/wp-json\/wp\/v2\/tags?post=346"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}